xA L4-1.5L (1NZ-FE) (2006)
Compressor Pulley: Testing and Inspection
Initial Inspection
INSPECTION
1. INSPECT COMPRESSOR WITH PULLEY ASSEMBLY
a. Measure the resistance between terminals 1 and 2.
Standard resistance: 160 to 320 Ohms at 20 degree C (68 degree F)
If the value is not as specified, replace the compressor assembly.