Canister Purge Control Valve: Service and Repair

REMOVAL

1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

CAUTION:  Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt
pretensioner activation.

2. REMOVE AIR CLEANER CAP

a. Disconnect the MAF meter connector.
b. Disconnect the purge VSV connector.
c. Disconnect the 2 wire harness clamps from the air cleaner cap.
d. Disconnect the 2 purge line hoses.
e. Disconnect the purge line hose from the hose clamp.
f.

Unlock the 2 clamps holding the air cleaner cap to the air cleaner case.

g. Loosen the hose clamp and remove the air cleaner cap.

3. REMOVE PURGE VSV

a. Remove the screw and purge VSV.

INSTALLATION

1. INSTALL PURGE VSV

a. Install the purge VSV with the screw.