scion Workshop Repair Guides

Scion Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 2863 > < Diagram Information and Instructions|Page 2861
Page 16
background image

1. When disconnecting a connector, first squeeze the mating halves tightly together to release the lock, and then press the lock claw and separate

the connector.

2. When disconnecting a connector, do not pull on the harnesses. Grasp the connector directly and separate it.
3. Before connecting a connector, check that there are no deformed, damaged, loose or missing terminals.
4. When connecting a connector, press firmly until it locks with a "click" sound.
5. If checking a connector with a TOYOTA electrical tester, check the connector from the backside (harness side) using a mini test lead.

NOTE:
-

As a waterproof connector cannot be checked from the backside, check it by connecting a sub-harness.

-

Do not damage the terminals by moving the inserted tester needle.

c. CHECKING CONNECTORS

1. Checking when a connector is connected: Squeeze the connector together to confirm that they are fully connected and locked.
2. Checking when a connector is disconnected: Check by pulling the wire harness lightly from the backside of the connector. Look for unlatched

terminals, missing terminals, loose crimps or broken conductor wires. Check visually for corrosion, metallic or foreign matter and water, and
bent, rusted, overheated, contaminated, or deformed terminals.

3. Checking the contact pressure of the terminal: Prepare a spare male terminal. Insert it into a female terminal, and check for ample tension when

inserting and after full engagement.

NOTE:  When testing a gold-plated female terminal, always use a gold-plated male terminal.

d. REPAIR METHOD OF CONNECTOR TERMINAL

1. If there is any foreign matter on the terminal, clean the contact point using an air gun or cloth. Never rub the contact point using sandpaper as

the plating may come off.

2. If there is abnormal contact pressure, replace the female terminal. If the male terminal is gold plated (gold color), use a gold-plated female

terminal; if it is silver-plated (silver color), use a silver-plated female terminal.

3. Damaged, deformed, or corroded terminals should be replaced. If the terminal does not lock into the housing, the housing may have to be