xA L4-1.5L (1NZ-FE) (2006)
Oxygen Sensor: Service and Repair
Heated Oxygen Sensor (For Bank 1 Sensor 1)
REMOVAL
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt
pretensioner activation.
2. REMOVE HEATED OXYGEN SENSOR
a. Disconnect the sensor connector.
b. Using SST, remove the sensor.
SST 09224-00010
INSTALLATION
1. INSTALL HEATED OXYGEN SENSOR
a. Using SST, install the sensor.