5. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

a. Using a vernier caliper, measure the exposed brush length.

Standard exposed length: 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed length: 4.5 mm (0.177 in.)

If the exposed length is less than the minimum, replace the brush holder assembly.