ABS/TCS - Zero Point Calibration Procedure|Page 41 > < ABS/TCS - Zero Point Calibration Procedure|Page 39
Page 7
background image

NOTE:

While performing the Zero Point Calibration, do NOT tilt, move, or shake the vehicle.
The vehicle must remain in a stationary condition throughout the entire process.
Be sure to perform the procedure on a level surface with an inclination of less than 1%.

3.

Drive the vehicle for at least 5 minutes to confirm Zero Point Calibration is complete.

NOTE:

If viewing Diagnostic Tester Data List after repair, the Steering Angle Sensor may remain at 1150 until the vehicle reaches 28 mph. This is a
normal condition until the learned values of the steering angle have been achieved.

Calibration Procedure With SST

Zero Point Calibration Using SST 09843-18040

The following procedure may be used in the cases where a Diagnostic Tester is not available.

NOTE:

While performing the Zero Point Calibration, do NOT tilt, move, or shake the vehicle.
The vehicle must remain in a stationary condition throughout the entire process.
Be sure to perform the procedure on a level surface with an inclination of less than 1%.

1.

If the vehicle is equipped with A/T, ensure that the shift lever is in the "P" range and the parking brake is applied. If the vehicle is equipped with a
M/T, ensure that the parking brake is applied.

2.

Turn the ignition switch ON.

ABS/TCS - Zero Point Calibration Procedure|Page 41 > < ABS/TCS - Zero Point Calibration Procedure|Page 39