A.

Turn the key to "IG-ON" then back to "OFF". Remove the key from the ignition switch. Close all doors (Figure 2).

B.

Using the remote control, press the unlock button one time. Open and close the driver's door within 30 seconds (Figure 3).

C.

Wait for 5 minutes.

CAUTION:

Verify that the amperage draw does NOT exceed the meter amperage rating. Otherwise, you may cause damage to the meter.

D.

Place the negative (-) terminal of the multimeter to the negative (-) terminal post of the battery and the positive (+) terminal of the
multimeter to the clamp of the negative (-) terminal battery cable (Figure 4).

Clip type leads will ensure continuous contact with terminals.

E.

Remove the negative (-) terminal clamp from the negative (-) terminal post of the battery.

NOTE:

The terminals of the multimeter MUST be in continuous contact before and during removal. Otherwise, the ECUs will wake up and you must
return to step 3A.

F.

Record the parasitic current draw.

^

If the current value is OVER 75mA, go to step 4.

^

If the current value is LESS than 75mA, then the RES ECU has NO problem. This TSB does NOT apply. Inspect for other causes of
excessive current draw.