xD L4-1.8L (2ZR-FE) (2008)
(f) Install and lock the air cleaner cap and air cleaner hose and then tighten the air cleaner hose clamp.
Torque: 3.0 Nm (31 kgf-cm, 27 in-lbf)
(g) Connect the No. 2 ventilation hose.
2. INSTALL MASS AIR FLOW METER See: Air Flow Meter/Sensor/Service and Repair/Installation