Heating, air conditioning|Heating > < Self-diagnosis and fault finding with the Vehicle Diagnosis, Testing and Information System VAS 5051
Fault table
   
Fault table
  Note!
t  There follows the list of all possible faults detected by the Autoclima control unit -J255-, which are printed in the -V.A.G 1551-, ordered according to the 5 digit fault codes.
t  If the faults occur only from time to time, these faults are indicated as “sporadic faults” (“SP”).
t  The fault code only appears on the printout.
t  The fault type may also appear on the fault table.
t  After the repair, the fault memory of the fault reader -V.A.G 1551- must always be cleared and consulted once more.
t  If, despite a claim made by the Autoclima, no fault is detected, the function “activator diagnosis 03” ( → Chapter) must be carried out, as well as the function “read measurement value block 08” ( → Chapter). If the display should blink, even though no fault has been detected, the functions must both be carried out, one after the other. If necessary, a fault localisation will have to be undertaken ⇒ Fault localisation Heating, air conditioning.
Printout in -V.A.G 1551- printerPossible cause of the faultFault elimination
00000

No fault detected


If after carrying out the repair “No fault detected” appears, the self-diagnosis is at an end.
If the display continues to blink, the following functions must be performed one after the other:
04 Begin basic adjustment → Chapter
00532
Supply voltage





Signal too small / SP → Note


Alternator faulty




Cables or connectors to the Autoclima control unit -J255-


Check the supply voltage (voltage on terminal 15) by “read measurement value block 08”
→ Chapter

Check the alternator:
→ Current flow diagrams, Electrical fault finding and Fitting locations

–  Check the supply voltage (voltage on terminal 15) by “read measurement value block 08” → Anchor
–  Check the cables and connectors against the current circuit diagram

–  Check the alternator:
→ Current flow diagrams, Electrical fault finding and Fitting locations

1)  One of the following indication is also added to the corresponding part.
   
Printout in -V.A.G 1551- printerPossible cause of the faultFault elimination
00600

Potentiometer -G92- in the servomotor -V68- (for temperature sensor) → Note
–  Short-circuit against ground /SP.
–  Interruption short-circuit against positive /SP.
–  Self-adaptation limit exceeded → Note
–  Short-circuit, cable breakage or error in the contacts of the connectors between -G92- and -J225-.
–  Temperature sensor moving with difficulty.
–  Potentiometer -G92- in -V68-, faulty.
–  Locate and eliminate the short-circuit, the cable breakage or the error in the contacts of the connectors, by following the current circuit diagram.
–  Check the freedom of movement of the temperature sensor → Note.
–  Replace the servomotor -V68-.

2)  If there is a fault in the potentiometer -G92-, by pressing the keys “+” or “-” to pre-select the temperature, the servomotor may be adjusted manually -V68- (indication margin between 0º C and 50º C).
3)  This fault is only detected during basic adjustment.
4)  Both final limits must be reached.
   
Printout in -V.A.G 1551- printerPossible cause of the faultFault elimination
00625

Speed signal.
–  Signal mot plausible /SP.
–  Loose contact in the wiring between the speed transmitter -G68-, the instrument panel or other component also connected to the signal (e.g. Autorradio or control unit for GRA) of the -E87-.
–  The tachometer -G21- or the instrument panel supplies a useless signal or one of the components connected destroys the signal.
–  Locate and eliminate the loose connection following the current circuit diagram.
–  Check the speed signal of the transmitter -G21- or the instrument panel (check all the components connected to this data transmission line). → Electrical system; Rep. Gr.90
00716


Servomotor for circulating air flap
-V113- → Note



Short circuit or breakage in the cables or connectors to the servomotor for the circulating air flap -V113-
-V113- blocked





-V113- faulty


–  Check -V113- by “read measurement value block” → Chapter

–  Check cables and connectors along the current circuit diagram

–  Carry out activator diagnosis 03 → Anchor

–  Replace -V113- and begin function 04 “Basic adjustment”.

5)  This fault is detected during basic adjustment 04, activator diagnosis 03 and in normal working. Both end limits should be reached.
   
Printout in -V.A.G 1551- printerPossible cause of the faultFault elimination
00779

External temperature sensor -G17-

Interruption/short circuit to positive → Note

Short circuit to ground → Note



Short circuit to positive or break in the cable or connectors of the external temperature sensor -G17-


Short circuit to ground in cables or connectors to the external temperature sensor -G17-.


-G17- faulty


–  Check -G17- by “read measurement value block” → Chapter
–  Check cables and connectors following the current circuit diagrams

–  Check -G17- by “read measurement value block” → Chapter
–  Check cables and connectors following the current circuit diagrams

–  Replace -G17-

6)  One of these indications appears in addition to the corresponding part.
   
Printout in -V.A.G 1551- printerPossible cause of the faultFault elimination
00785

Control panel thermosensor -G56-.
–  Short circuit against ground /SP.
–  Interruption, short circuit against positive /SP.
–  Short circuit or cable break between -G56- and -J255-.
–  Thermosensor -G56-, faulty.
–  Locate and eliminate the short circuit or the break in the cables following the current circuit diagram.
–  Check the thermosensor -G56- (electrical verification, → Anchor)
00792

Pressure gauge for the air conditioner -F129-.
–  Short circuit to ground /SP.
–  Brake in the wiring connection between -F129- and -E87-.
–  Fault in the activation of the fan for the cooling fluid -V7- (step 1).
–  Dirty condenser or radiator.
–  Fault in the activation of the fan for the cooling fluid -V7- (step 2) of the pressure gauge -F129-.
–  Pressure gauge -F129-, faulty.
–  Fault in the cooling agent circuit (overload or depression).
–  Locate and eliminate the short circuit or the loose contact following the current circuit diagram.
–  Check the activation of the fan -V7- (step 1) : activator diagnosis, → Chapter electrical verification, → Anchor.
–  Clean the condenser and the radiator.
–  Check the activation of the fan for the cooling fluid -V7- (step 2, by means of pressure gauge -F129-), and the control unit for the cooling fluid fan -J293-.
–  Check the pressure gauge -F129- ( → Chapter).

  Note!
The pressure gauge -F129- is composed of two control elements:
–  By means of contacts 1 and 2, the compressor will be disconnected if there is depression or overload in the cooling agent circuit the switch opens the passage).
–  By means of contacts 3 and 4 the fan for the cooling fluid is connected to the 2nd step (the switch closes the passage).
   
Printout in -V.A.G 1551- printerPossible cause of the faultFault elimination
00796

Ventilator for the thermal probe of the instrument panel -V42-.
–  Blockage or lack of voltage /SP.
–  Break in the voltage supply to -V42- or in the wiring between -V42- and -E87-.
–  Blower -V42-, faulty.
–  Locate and eliminate the break in the wiring following the current circuit diagram.
–  Replace blower -V42-.

01271

Servomotor for the temperature flap -V68- → Note


Short circuit of break in the wiring or connectors to the servomotor for the temperature flap -V68-

The -V68- has been fitted without carrying out the function “04 Begin basic adjustment”.

-V68- blocked

-V68- faulty


–  Check -V68- by “read measurement value block” → Chapter
–  Check cables and connectors along the current circuit diagram

–  Check the final position of the servomotor -V68-, once fitted → Anchor
–  Carry out diagnosis of the activators 03 → Chapter
–  Replace -V68- and commence function 04 “basic adjustment”.

7)  This fault is detected during basic adjustment 04; the activator diagnosis 03 and in normal working. Both final limits should be reached.
   
Printout in -V.A.G 1551- printerPossible cause of the faultFault elimination
01273

Cool air fan -V2- or control unit for the cool air fan -J126-


Short circuit or break in cables or connectors to the cool air ventilator -V2-


Control unit for fan -J126- or cool air ventilator -V2- faulty


–  Check -V2- by “read measurement value block” → Chapter
–  Check cables and connections along the current circuit diagrams

–  Carry out activator diagnosis 03 → Chapter

–  Replace -J126- ó -V2-
01296

Temperature transmitter in central diffuser -G191-


Break / short circuit to positive


Short circuit to ground






There is no transmitter for the central temperature diffuser -G191-






–  Then select the following function:
04 Begin basic adjustment
→ Chapter
01297

Temperature transmitter of the footrest area diffuser -G192-

Break / short circuit to positive




Short circuit to ground





Short circuit to ground or break in the cables or connectors to the temperature transmitter of the footrest area diffusers -G192-



Short circuit to ground or break in the cables or connectors to the temperature transmitter of the footrest area diffusers -G192-


-G192- defective





–  Check the -G192- by “read measurement value block” → Chapter
–  Check the cables and connector along the current circuit diagrams.

–  Check the -G192- by “read measurement value block” → Anchor
–  Check the cables and connector along the current circuit diagrams.
–  Replace -G192-
65535

Control unit -J255-


Cables or connectors to the control unit for Autoclima -J255-






Control unit for Autoclima defective


–  Check the cables and connector along the current circuit diagrams.
–  Check the control unit for Autoclima -J255- by “read measurement value block” → Chapter


Replace the control unit for Autoclima -J255-. The select the following function:
04 Begin basic adjustment → Chapter

   

Heating, air conditioning|Heating > < Self-diagnosis and fault finding with the Vehicle Diagnosis, Testing and Information System VAS 5051