Fault table |
Note!
t | There follows the list of all possible faults detected by the Autoclima control unit -J255-, which are printed in the -V.A.G 1551-, ordered according to the 5 digit fault codes. |
t | If the faults occur only from time to time, these faults are indicated as “sporadic faults” (“SP”). |
t | The fault code only appears on the printout. |
t | The fault type may also appear on the fault table. |
t | After the repair, the fault memory of the fault reader -V.A.G 1551- must always be cleared and consulted once more. |
t | If, despite a claim made by the Autoclima, no fault is detected, the function “activator diagnosis 03” ( → Chapter) must be carried out, as well as the function “read measurement value block 08” ( → Chapter). If the display should blink, even though no fault has been detected, the functions must both be carried out, one after the other. If necessary, a fault localisation will have to be undertaken ⇒ Fault localisation Heating, air conditioning. |
Printout in -V.A.G 1551- printer | Possible cause of the fault | Fault elimination | ||||||
00000 No fault detected | If after carrying out the repair “No fault detected” appears, the self-diagnosis is at an end. If the display continues to blink, the following functions must be performed one after the other: 04 Begin basic adjustment → Chapter | |||||||
00532 Supply voltage Signal too small / SP → Note | Alternator faulty Cables or connectors to the Autoclima control unit -J255- | Check the supply voltage (voltage on terminal 15) by “read measurement value block 08” → Chapter Check the alternator: → Current flow diagrams, Electrical fault finding and Fitting locations
|
1) | One of the following indication is also added to the corresponding part. |
Printout in -V.A.G 1551- printer | Possible cause of the fault | Fault elimination | ||||||||||||||||||
00600 Potentiometer -G92- in the servomotor -V68- (for temperature sensor) → Note
|
|
|
3) | This fault is only detected during basic adjustment. |
4) | Both final limits must be reached. |
Printout in -V.A.G 1551- printer | Possible cause of the fault | Fault elimination | ||||||||||
00625 Speed signal.
|
|
| ||||||||||
00716 Servomotor for circulating air flap -V113- → Note | Short circuit or breakage in the cables or connectors to the servomotor for the circulating air flap -V113- -V113- blocked -V113- faulty |
|
5) | This fault is detected during basic adjustment 04, activator diagnosis 03 and in normal working. Both end limits should be reached. |
Printout in -V.A.G 1551- printer | Possible cause of the fault | Fault elimination | ||||||||||
00779 External temperature sensor -G17- Interruption/short circuit to positive → Note Short circuit to ground → Note | Short circuit to positive or break in the cable or connectors of the external temperature sensor -G17- Short circuit to ground in cables or connectors to the external temperature sensor -G17-. -G17- faulty |
|
6) | One of these indications appears in addition to the corresponding part. |
Printout in -V.A.G 1551- printer | Possible cause of the fault | Fault elimination | ||||||||||||||||||||||||
00785 Control panel thermosensor -G56-.
|
|
| ||||||||||||||||||||||||
00792 Pressure gauge for the air conditioner -F129-.
|
|
|
Note!
The pressure gauge -F129- is composed of two control elements: |
– | By means of contacts 1 and 2, the compressor will be disconnected if there is depression or overload in the cooling agent circuit the switch opens the passage). |
– | By means of contacts 3 and 4 the fan for the cooling fluid is connected to the 2nd step (the switch closes the passage). |
Printout in -V.A.G 1551- printer | Possible cause of the fault | Fault elimination | ||||||||||
00796 Ventilator for the thermal probe of the instrument panel -V42-.
|
|
| ||||||||||
01271 Servomotor for the temperature flap -V68- → Note | Short circuit of break in the wiring or connectors to the servomotor for the temperature flap -V68- The -V68- has been fitted without carrying out the function “04 Begin basic adjustment”. -V68- blocked -V68- faulty |
|
7) | This fault is detected during basic adjustment 04; the activator diagnosis 03 and in normal working. Both final limits should be reached. |
Printout in -V.A.G 1551- printer | Possible cause of the fault | Fault elimination | ||||||||||
01273 Cool air fan -V2- or control unit for the cool air fan -J126- | Short circuit or break in cables or connectors to the cool air ventilator -V2- Control unit for fan -J126- or cool air ventilator -V2- faulty |
| ||||||||||
01296 Temperature transmitter in central diffuser -G191- Break / short circuit to positive Short circuit to ground | There is no transmitter for the central temperature diffuser -G191- |
→ Chapter | ||||||||||
01297 Temperature transmitter of the footrest area diffuser -G192- Break / short circuit to positive Short circuit to ground | Short circuit to ground or break in the cables or connectors to the temperature transmitter of the footrest area diffusers -G192- Short circuit to ground or break in the cables or connectors to the temperature transmitter of the footrest area diffusers -G192- -G192- defective |
| ||||||||||
65535 Control unit -J255- | Cables or connectors to the control unit for Autoclima -J255- Control unit for Autoclima defective |
Replace the control unit for Autoclima -J255-. The select the following function: 04 Begin basic adjustment → Chapter |