Attach the unit -V.A.G. 1551- (-V.A.G. 1552-). Switch on the ignition and enter “direction code” 01 to select the engine control unit. (Fault finder: Connect and select the engine control unit → Vehicle diagnosis, testing and information system VAS 5051.)
Display reading:
–
Press the 0 and 8 buttons for the function “Read measurement values block” and confirm the entry with the Q button.
Rapid data transfer HELP
Select function XX
Display reading:
–
Press buttons 0, 0, and 5 for “Display group number 99” and confirm the entry by pressing the Q button.
Read measurement values block HELP
Enter display group number XXX
Display reading: (1...4 = display fields)
–
Read the value displayed in field 2. Theoretical value: 11.5 V at least
–
Press the button →.
–
Press buttons 0 and 6 for the function “End data transmission” and confirm the entry with the Q button.
–
Switch off the ignition.
If the theoretical value is not attained
Read measurement values block 5 →
1 2 3 4
–
Attach the test box -V.A.G. 1598/22- to the control unit cabling harness.