Reading on display: (1...4 = display fields) |
–
| Watch the value in field 2: (3rd and 4th digits to the left) Target value: 0 0 0 0 |
–
| Depress the brake pedal all the way and watch the value in field 2: Target value: 0 0 1 1 Meaning of the numbers → Anchor |
–
| Press 0 and 6 for the function “End transmission” and confirm the entry with the Q key. |
–
| Switch off the ignition. |
If the target value is not reached: |
–
| Disconnect the connector from the brake light/brake pedal switch. |
–
| To measure the resistance, connect the multimeter between switch contacts 1 and 4. Target value: ∞ Ω (no flow) |
–
| Depress the brake pedal. Target value: 0.0 Ω approx. |
|
|
Read measured value block 66 → | |
|