| Unscrew the nuts -arrows- that secure the front of the casing -arrows-. |
–
| Separate the floor protection lining, lower part. |
–
| Remove cross member -B- located below the exhaust gas system. |
–
| Separate the exhaust gas system by the double clamp behind the front section of the exhaust tube → Rep. Gr.26. |
–
| Remove the thermal protection. |
–
| Release the gear lever casing from the bodywork. |
–
| Turn protective housing on shift lever downward and remove together with lines. When doing this, do not damage mechanical parts and body. |
|
|
|