Carry out check measurement - checking dimension “r” |
Insert universal test gauge and measure dimension “r”. |
If the correct shims have been selected, the dial gauge, read anti-clockwise on the red scale, must now indicate the calculated allowance “r” within a tolerance of +0.04 mm. |
|
|
|