Leon Mk2
Note
t | Installation is described only for the left side. The right side is similar. |
t | Remove protective backing immediately before installation. Working temperature of all parts approx. 21° C. |
t | Curing period before fitting securing bolts is at least 2 hours at a room temperature of about 21 °C. |
t | Use only adhesive remover -D 002 000 10- as cleaning agent. |
t | The retaining strip must be bonded in place immediately following cleaning. |
– | Immediately before bonding retaining strip, clean bonding surface thoroughly with adhesive remover -D 002 000 10-. |
– | Pull protective film -5- off retaining strip -1- immediately prior to installation. |
l | Bonding surfaces must be free of dust and grease. |
– | Apply retaining strip -1- evenly on side member -7-. |
– | Press retaining strip forcefully with roller for door insulation film -3356- in area of adhesive tape. |
Caution
|
Side member without holes |
– | Drill out holes with a 1.5 mm drill bit. |
– | Screw in self-tapping screws -2- with cordless drill/driver -VAS 5036-, using the highest speed, until the screw bites. Remove cordless drill/driver immediately. |
Side member with holes |
– | Tighten bolts -2- with least possible torque so that bolt is not over tightened. |
– | Then screw in bolts -3 and 4-. |
Specified torque for bolts -2, 3 and 4-: 1.5 Nm. |