Motronic injection and ignition system
Checking control unit voltage supply
Special tools, testers, measuring instruments and auxiliary items required
-
◆ Fault reader V.A.G 1551 or vehicle system tester V.A.G 1552 with cable V.A.G 1551/3
-
◆ Test box V.A.G 1598/18
-
◆ Hand multimeter V.A.G 1526 or multimeter V.A.G 1715
-
◆ Adapter set V.A.G 1594
-
◆ Current flow diagram
Check conditions
-
● Battery voltage at least 11.5 V
-
● Fuses No. 15 and 18 OK.
-
● Alternator OK, checking:
=> Current flow diagrams, Electrical fault finding and fitting locations binder
Test sequence
-
‒ Connect fault reader V.A.G 1551 (V.A.G 1552) and select engine electronics control unit (address word 01); carry out selection at idling.
|