Functional check of sender
-
‒ Observe coolant temperature figure in display zone 2. The temperature figure must
Increase uniformly and without interruption.
- If a temperature figure is displayed which deviates greatly from the sender's ambient temperature, check sender wiring for transfer resistances.
Notes:
-
◆ Depending upon the temperature level, the display on fault reader will jump by 1.5...5.0 °C
-
◆ If irregular engine running occurs in certain temperature ranges and the temperature figure does not increase without interruption, the temperature signal is temporarily interrupted and the sender must be renewed.
-
◆ Open circuit is indicated by -46.5 °C.
-
‒ Press ⇒ key.
-
‒ In put 06 for "End output" and confirm with Q.
-
‒ Switch off ignition
If the figure does not increase uniformly:
-
‒ Replace coolant temperature sender (G62)
, item 7.
If a coolant temperature sender fault is indicated in fault memory even through the figure increases uniformly:
-
‒ Remove dash panel insert:
=> Electrical system; Repair group 90
|