seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Coding Simos control unit > < Technical data of self diagnosis
Simos injection and ignition system
Self diagnosis
Connecting fault reader V.A.G 1551 and selecting engine electronics control unit

Special tools, testers and auxiliary items

  • ◆ Fault reader V.A.G 1551 or vehicle system tester V.A.G 1552 with cable V.A.G 1551/3

Note:

The vehicle system tester V.A.G 1552 can be used instead of the fault reader V.A.G 1551, however a print-out is not possible.

Test conditions

  • ● Fuse15 OK.
 
N69-0007
  • ● Battery voltage at least 11 V
  • ● Earth connections on engine and gearbox OK.
    (Earth connection engine: , Item 17).

Work sequence

  • ‒ → Lever cover -1- or ashtray housing out from centre console.
  • ‒ Connect fault reader or system tester using cable V.A.G 1551/3 to diagnosis connection.
  • ‒ Depending upon desired function:
    Switch ignition on
        or
    Start engine , Table "Selectable functions".

Notes:

  • ◆ If the display does not indicate as described in the work sequence:

=> Fault reader operating instructions

  • ◆ If due to an input fault "Fault in the data transfer!" is displayed, pull wire off fault reader, reconnect and repeat work step.
  • ‒ Operate fault reader taking into account the information on the display:
  • ‒ Press key 1 for "Rapid data transfer".
  • ‒ Press keys 0 and 1 for address word "Engine electronics" and confirm entry with Q key.
 
→ The fault reader V.A.G 1551 display will show the control unit identification, e.g.:
037 906 025 B    SIMOS 4S    XXXX⇒
Coding 0000    WSC XXXXX
  • ◆ 037 906 025 B = Part No. of the control unit (see parts catalogue for latest control unit version)
  • ◆ SIMOS 4S = System designation and version
  • ◆ XXXX = Programme level number
  • ◆ Coding 00000 = Coding variants
  • ◆ WSC = Workshop code

If the coding differs from the vehicle version, then:

  • ‒ Check control unit coding => Page 01-6,
    Coding Simos control unit
  • ‒ Press the ⇒key.
 
→ Indicated on display:
Rapid data transfer    HELP
Select function XX
  • ‒ Further measures see repair procedures.

Coding Simos control unit > < Technical data of self diagnosis