seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Clearing refrigerant circuit of contaminants > < Searching for leaks in refrigerant circuits using leak detector V.A.G 1796
Detecting leaks in refrigerant circuit using leak detecting systemVAS 6196 or leak detecting systemVAS 6201.
Detecting leaks in refrigerant circuit using leak detecting system -VAS 6196- or leak detecting system -VAS 6201-.
   
Leak detecting system -VAS 6196-
or
  W00-10195
Leak detecting system -VAS 6201-
  Note!
Small leaks can be made visible, for example, by using a fluorescent leak detection additive -VAS 6196/1-.
Leak detection:
–  If the refrigerant circuit is completely empty, charge with about 100 grams of refrigerant.
–  Introduce leak detection additive -VAS 6196/1- into refrigerant circuit and use a UV lamp to examine refrigerant circuit.
  Note!
The leak detection additive can be allowed to remain in the refrigerant circuit.
  A87-0504