seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Electrical components not installed in refrigerant circuit > < Refrigerant circulation solenoid valve N43
A/C compressor regulating valve, air conditioning systemN280
A/C compressor regulating valve, air conditioning system -N280-
   
The regulating valve is fitted to the air conditioner compressor. It is activated by the operating and display unit for Climatronic air conditioning system -E87- or the Climatronic control unit -J255- The regulating valve influences the pressure in the low-pressure side and thus the temperature at the evaporator.
  Note!
The A/C compressor regulating valve, air conditioning system -N280- is an integral part of the A/C compressor and cannot be replaced individually.
  A87-0378