If there is still refrigerant in the refrigerant circuit > < In the event of leaking or damaged components (apart from the air conditioner compressor, receiver or reservoir)
If the refrigerant circuit was completely empty
If the refrigerant circuit was completely empty
–  Remove defective part.
–  Remove air conditioner compressor.
–  Remove oil drain screw from air conditioner compressor.
  Note!
t  If the air conditioner compressor is a “Denso” (“Nippondenso”) type, in the oil drain screw there is a sealing ring instead of an O-ring; always renew this → Parts catalogue.
t  To speed up the draining of the refrigerant oil, rotate the shaft of the air conditioner compressor using the magnetic clutch pulley.
t  Pour old refrigerant oil out of the air conditioner compressor; Handling refrigerant oil, see Service Division/ServiceNet; Handbooks; Service Organisation Handbook; Volume 2, Environment; Emissions protection; Refrigerant from air conditioning systems / Refrigerant machine oils.
t  Then fill the A/C compressor with the quantity of new refrigerant oil corresponding to the quantity in a genuine A/C compressor → Rep. Gr.87.
t  Different types and quantities of refrigerant oils are required for different air conditioner compressors → Rep. Gr.87.
t  To ensure proper lubrication of the air conditioner compressor when it runs for the first time, the air conditioner compressor must be filled with at least 80 cm3 of refrigerant oil; the remainder can be poured into the new reservoir or receiver → Rep. Gr.87.
t  If dirt enters the air conditioner compressor whilst the refrigerant circuit is open (e.g. after an accident), the air conditioner compressor should be renewed.
t  Cleaning the refrigerant circuit with compressed air or nitrogen (purging) → Chapter.
–  Renew receiver or reservoir and restrictor.
–  Assemble the refrigerant circuit, evacuate it and charge it.
   