Removing thermostat for 2nd heat exchanger |
Note t
| Opens the 2nd heat exchanger as the coolant temperature rises. Starts opening at approx. 50° C, fully opened at approx. 65° C. |
t
| The identification -V- on the picture indicates coolant supply from engine to heat exchanger. |
t
| Note the installation position. Collar -2- must point towards the 2nd heat exchanger. |
t
| Cooling system is pressurized when engine is warm. If necessary, release pressure before carrying out repairs. |
t
| Refill with coolant after installing the thermostat → Rep. Gr.19. |
–
| Remove thermostat -1- for 2nd heat exchanger. |
|
|
|