| Instructions for repair work on vehicles with air conditioning and how to work with the refrigerant |

Note | t
| A label on the lock carrier indicates the type and quantity of refrigerant used. |

Note | The connections for the senders/switches described in this Workshop Manual are fitted with a valve which closes automatically when the switches are unscrewed. For this reason, this switch may be replaced in any Seat workshop when the air conditioning system is replaced. |

Caution | Refrigerant lines must not be bent to a radius less than r = 100 mm. |
| There is a film in the refrigerant lines which can be destroyed. |
|
| t
| Safety measures when handling refrigerant → Chapter |
| t
| Safety measures for vehicles with start/stop system → Chapter |
| t
| Working on refrigerant circuit / discharging refrigerant circuit → Chapter |
| t
| Paintwork on vehicles with air conditioning system → Chapter |
|
|
|