Repair work on refrigerant circuit which may only be carried out in suitable workshops by specially trained mechanics, vehicles ► 05.00 |
WARNING Danger of freezing injuries. |
If refrigerant circuit has not been evacuated, refrigerant and refrigerant oil will escape. |
Extract refrigerant before opening refrigerant circuit. If the refrigerant circuit is not opened within 10 minutes after it has been evacuated, pressure may develop in refrigerant circuit due to re-evaporation. Extract refrigerant again. |
|
Note t
| The refrigerant circuit must be purged with refrigerant R134a: |
t
| If dirt or other contamination is in the circuit. |
t
| If during the evacuation of a leak-tight refrigerant circuit the vacuum is not maintained at the gauge (there is moisture in the refrigerant circuit and this generates vapour pressure). |
t
| If the refrigerant circuit has been left open for longer than normally required for repairs (e.g. following an accident). |
t
| Pressure and temperature measurements in the refrigerant circuit indicate that there is moisture in the refrigerant circuit. |
t
| There is doubt about the amount of refrigerant oil in the refrigerant circuit. |
t
| The air conditioner compressor has to be exchanged because of internal damage (e.g. noisy or lack of power). |
t
| The procedure for purging can be found in the Workshop Manual Air conditioning system with refrigerant R134a → Rep. Gr.00; Technical data; Purging (cleaning) refrigerant circuit with refrigerant R134a. |
|
|
|