Heating, air conditioning|Heating > < Read measured value block
Table of available display group numbers
Table of available display group numbers
  Note
Check the values for measurements specified in the following tables using the applicable current flow diagram for Climatronic.
   
Display groupDisplay zoneDesignation
11-G17-(-XX to +XXX° C)
  Ambient temperature sensor
    
 2-G152-(-XX to +XXX° C)
  Front vent temperature sender
    
 3-G174-(-XX to +XXX° C)
  Rear vent temperature sender
    
 4-G110-(XX to +XXX° C)
  Coolant temperature sender

   
Display groupDisplay zoneDesignation
21-G22-(0 to XXX)
  Speedometer sender
    
 2-G107-(0 to XX%)
  Sunlight penetration photosensor
    
 3-G56-(-XX to +XXX° C)
  Dash panel temperature sensor
    
 4Supply voltage (tl. 30)

   
Display groupDisplay zoneDesignation
31-V2-(0.0 to XX.X V)
  Fresh air blower
    
 2-V80-(0.0 to XX.X V)
  Rear fresh air blower
    
 3No value on display
    
 4No value on display

   
Display groupDisplay zoneDesignation
41-F129- 
   Air conditioning system pressure switch:
  Value: 10
  2/32 bar “on”; 16 bar “off”
  Value: 11
  2/32 bar “on”; 16 bar “on”
  Value: 00
  2/32 bar “off”; 16 bar “off”
  Value: 01
  2/32 bar “off”; 16 bar “on”
 2Air conditioning system ready/engine start
  Value: 10
  ACS ready “on”; engine “off”
  Value: 11
  ACS ready “on”; engine “on”
  Value: 01
  ACS ready “off”; engine “on”
  Value: 00
  ACS ready “off”; engine “off”
 3-F8- 
  Kick-down switch
  Value: 1 “on”
  Value: 0 “off”

   
Display groupDisplay zoneDesignation
51Auxiliary coolant heater
  Value: “on”; “off”
 2Terminal 58
  Value: “on”; “off”
 3X terminal
  Value: “on”; “off”

   
Display groupDisplay zoneDesignation
61Front temperature flap position
  Value (0 to XXX %)
 2Front air distribution flap position
  Value (0 to XXX %)
 3Centre vent flap position
  Value (0 to XXX %)
 4Fresh air and air recirculation flap position
  Value (0 to XXX %)

   
Display groupDisplay zoneDesignation
71Rear temperature flap position
  Value (0 to XXX %)
 2 → NoteRear air distribution flap position
  Value (0 to XXX %)

1)  For code 00010 (air conditioning in front only), the rear air distribution flap motor does not exist.
   
Display groupDisplay zoneDesignation
81Actual value for air conditioner compressor
  Value: “on”; “off”
 2Specification for air conditioner compressor requirement
  Value: “on”; “off”
 3Code for air conditioner compressor “OFF”
  Value (0 to 16 → Note)

2)  The number displayed on diagnosis tester is explained in the following table.
   
Switch-off codeMeaningRemark
0NoneFunction OK
1 → NoteHigh-pressure eventPressure 2...32 bar
> 32 bar “off”, 16 bar “on”
2Blower defective and currentactual 3 V 
3 → NoteLow-pressure eventPressure < 2 bar
2/32 bar “off”, 16 bar “on”
54 seconds after engine startNo engine start detected with terminal 15 on.
v=0 km/h and no flank change (no voltage indicated) from terminal 15.
6ECON modeAC function not activated
7Air conditioning OFFBlower switch in position 0
8Function of ambient temperatureAmbient temperature < = +3° C
10Low voltagesee TL 80101 Point 2.2
11 → NoteEngine temperatureEngine temperature > 118° C
13Excess voltagesee TL 80101 Point 2.2
16Air conditioner compressor actuationDue to fault source in actuation path
⇒radiator fan control unit switch-off
⇒engine control unit switch-off
⇒gearbox control unit switch-off
⇒magnetic clutch control unit switch-off
etc.

3)  If engine code 1 is selected in code table (0), the above-named codes for air conditioner compressor “OFF” are not applicable because the air conditioning system pressure switch -F129- is not installed. If the air conditioner switches off in spite of a demand signal, a "16" will appear in the fourth position of display group 8.
   
Display groupDisplay zoneDesignation
91Windscreen heater
  Value: “on”; “off”
 2Windscreen heating “on” remaining time in seconds
  XXX.X 0 -s → Note/ - → Note
 3Windscreen wiper signal
  Value: “on”; “off”

4)  Display range from maximum 240 seconds (minimum setting 60 seconds) to 0 seconds. This time display will only be activated or deactivated with the defrost function button. If the ambient temperature is greater than 10° C, the windscreen heating cannot be activated using the defrost function button.
5)  It will be indicated whether the windscreen heating was not switched on by the Climatronic or the windscreen heating is switched off.
   