t
| On the condensation drainage valve -C- there is no flap. |
t
| Check in case of a complaint of humidity in the passenger compartment, apart from the condensation drainage, the following components: |
t
| the correct fitting of the plenum chamber cover and the cover for the air inlet opening, also check for damage → Chapter. |
t
| the correct fitting of the dust and pollen filter and if it is dirty → Chapter. |
t
| the forced ventilation vents in the boot → Chapter. |
t
| Check the temperature of the evaporator air outlet using the measurement of the Air temperature sender, evaporator outlet -G263- in the conditions of use described by the client, or by the conditions of use described below in the Climatronic control unit -J255- → Vehicle diagnosis, testing and information system VAS 5051. |
t
| Select the lowest temperature possible for the passenger and driver side |
t
| If the measurement value of the sender is too low (for an atmospheric temperature above 0°C, less than 0°C for a long period of time) or too high (even if the air conditioning functions correctly above about 10°C, for example), see the notes for the refrigeration performance test → Chapter. |
|
|
|