Air conditioner heat exchanger (heating): Removing and installing > < Air flow in the evaporator housing
Air flow in the air distribution housing
Air flow in the air distribution housing
  Note
To show the air flow in the air distribution housing the air is represented by the lines “A”-“A” and “B”-“B”.
   
1 - Air distributor housing
2 - Left temperature trap
q   Shown in “cool”position
3 - Air flow to the centre console rear vent air duct and to the centre vents of the dashboard
4 - Air flow to the centre console rear vent air duct and to the centre vents of the dashboard
5 - Right temperature flap
q   Shown in centre position
6 - Left foot well temperature trap
q   Shown in “closed ”position
q   The centre vents (left, right and middle) and the vents in the foot well area are operated by the cam disks on the servomotor or the shaft.
7 - Left foot well air duct
8 - Air distribution housing crossed by the line “A”-“A”
9 - Additional heating element -Z35- with Additional air heating control unit -J604-
q   Not fitted in all vehicles, see → Current flow diagrams, Electrical fault finding and Fitting locations
q   Only for vehicles fitted with a diesel engine, depending on the vehicle equipment there is an additional electric heating
10 - Heating system heat exchanger
11 - Air intake for the evaporator housing
12 - Right temperature flap
q   Shown in centre position
13 - Right foot well temperature trap
q   Shown in “closed ”position
q   The centre vents (left, right and middle) and the vents in the foot well area are operated by the cam disks on the servomotor or the shaft.
14 - De-icing vent
q   Shown in “closed ”position
15 - Air distribution housing crossed by the line “B” - “B”
16 - Centre flap “centre”
q   Shown in “open” position
q   The centre vents (left, right and middle) and the vents in the foot well area are operated by the cam disks on the servomotor or the shaft.
17 - Flap in the air flow duct to the centre console rear vent
q   This flap is operated by a transmission lever from the centre flap
18 - Air flow duct to the centre console rear vent
q   Now, this duct is closed by a plug
q   Use of a vent in the centre console still not realised

   