seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

The pressure signal of the High pressure sender G65 . > < Checking the pressure signal of the High pressure sender G65 .
Pin allocation on the High pressure senderG65
Pin allocation on the High pressure sender -G65-
   
Pin -1-: Earth.
Pin -2-: Signal output (rectangular signal to the Climatronic control unit -J255-/Air conditioning control unit -J301-).
Pin -3-: To the Onboard network control unit -J519-.
  Note
t  If the pin -A- is disconnected the compressor is not activated.
t  The high pressure sender -B- is an electronic control unit that generates a rectangular wave signal whose duty cycle changes with the pressure change in the refrigerant circuit → Chapter.
  A87-0637

The pressure signal of the High pressure sender G65 . > < Checking the pressure signal of the High pressure sender G65 .