t
| The duty signal is the result of the relationship between the width of the pulse -A- and the length of the signal -B-. |
–
| Depending on the adjustment in the Climatronic control unit -J255-/Air conditioning control unit -J301- and the magnitudes of the environment conditions measured, the amplitude of the rectangular wave signal (duty cycle between 100% and more than 30%, the regulation valve is activated in such a way that enough power is directed to the compressor to reach the specified temperatures). |
Note t
| With the setting of the lowest temperature, the air conditioning system compressor regulating valve -N280- is controlled in such a way that the maximum permissible flow of current flows with approx. 0.65 A through the air conditioning system compressor regulating valve -N280- (highest power of the compressor). |
t
| During regular operation, the controlling period depends on the required cooling output, the on-board voltage, etc. However, the controlling continues until an average current intensity of approx. 0.3 A flows. |
|
|
|