| Remove the servo motor -B- (in the direction of the arrow) from the air inlet opening. |
Note t
| The connection between the cogwheels of the servomotor and the dynamic pressure flap is designed is such a way that the servomotor may only be easily removed in the position „fresh air option“ (the opening for the air recirculation inlet option by the fresh air / air recirculation flap -A- is closed). |
t
| If the servo motor is in any other position and cannot be moved, it may not be extracted without first loosening the allotment points -C-, ensure to avoid any damage to the cogwheel -D- during this operation. |
|
|
|