seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Flexible axle (for air distribution): removing and fitting > < Control unit for heating and fresh air connectors
Pin allocation for the multi-connectors on the rear of the control unit for heating and fresh air
Pin allocation for the multi-connectors on the rear of the control unit for heating and fresh air
16-pin connector is vacant.
   
Electrical connector, 5-pin, T5
1 - 3rd blower speed
2 - 2nd blower speed
3 - 1st blower speed
4 - 4th blower speed
5 - Terminal X
  N80-10009
Electrical connector, 20-pin, T20 c
3 - fresh air and air recirculation flap servomotor -V154-
6 - fresh air and air recirculation flap servomotor -V154-
8 - Rear windscreen
11 - Heated driver seat regulator -E94- (optional equipment)
15 - Heated passenger seat regulator -E95- (optional equipment)
16 - Heater/heat output switch -E16-
18 - Terminal 30
19 - Terminal 15
20 - Terminal 31
  N80-10009