| –
| If the heating switch is closed, the electronics of the Heating control unit -J65-, with the ignition on, connects through pin „7“ earth to the Additional air heating control unit -J604-. The Additional air heating control unit -J604- detects that more heating power is required and activates the additional electric heating, if the remaining conditions for activation are fulfilled in the Additional air heating control unit -J604-. |
| t
| Connection conditions for electric additional heating (activation of the heating element for additional heating -Z35-) of the additional air heating control unit -J604- |
| t
| Connection conditions for independent heating as additional heating (in the additional heating control unit -J364-) in vehicles with the extra equipment → independent heating; Rep. gr. |

Note | In order for the relevant engine control unit to activate the heating element for additional heating -Z35- with three phases via the low temperature relay -J359- and the high temperature relay -J360-, the same conditions must be met in the engine control unit as in the air conditioning control unit -J301- in vehicles with manual climate control. |
| Connection criteria for activation of electric additional heating |
| –
| The engine control unit activates the low temperature relay -J359-, the high temperature relay -J360- and the heating element for additional heating -Z35- if the following prior conditions are met: |
| t
| The engine control unit receives an earth signal from the heating control unit -J65-. |
| t
| The engine has been running for at least 8 seconds and the engine speed is over 500 rpm. |
| t
| The engine temperature is below 75 °C |
| t
| Calculated ambient temperature is lower than 8° C |
| t
| The onboard voltage is over 12.2 V and the onboard network control unit -J519- does not send any signal to block the connection. |
| t
| No fault is stored in the engine control unit and the alternator -C- stress is below 30 ...77% (depending on the engine speed) |

Note | Disconnection criteria for additional heating |

Note | Vehicles without air conditioning cancel the activation if the engine control unit fails to meet the connection criteria, or detects one of the disconnection criteria. |
| t
| If one of the connection conditions is lost |
| t
| Calculated ambient temperature greater than 11° C |
| t
| The alternator -C-stress is over 95%. |
| t
| The engine control unit does not receive an earth signal from the heating control unit -J65-. |
|
|
|