–  Insert the flexible shaft into the regulation unit for the air distribution flaps and fit it in.
–  Place the anti-fog flap vertically (open) using the flexible shaft.
–  Set the heater air distribution control at position “Demist”.
–  At this setting, insert the flexible axle in the heater switch and fit into place.
  Note
t  If the instrument panel is fitted and the position of the demist flap is not visible, insert the flexible axle in the heater switch and fit into position. Start the fresh air fan at maximum level.
t  In the position “Anti-fog”, if air comes out of the anti-fog nozzle and not the floor nozzles, the flexible shaft is correctly installed. If this is not the case, remove the flexible axle from the heating switch, turn the rotary switch 1/2 way (180° ) and replace the flexible axle. Repeat the check.
   