Fault code number and meaning | Possible cause of fault | Fault rectification with remarks |
000 | | |
No malfunction | | |
001 | | |
Overvoltage warning (> 16 V) | Controller | Renew |
002 | | |
Undervoltage warning (< 10.2 V) | 2nd. battery | Charge |
010 | | |
Overvoltage shut-off (> 16 V) | 2nd. battery | Voltage was present for longer than 20 seconds |
011 | | |
Undervoltage shut-off (< 10.2 V) | 2nd. battery | Voltages were present for longer than 20 seconds |
012 | | |
Overheating | Temperature at flame monitor -G64- or overheating sensor -G189- too high (> 125 °C). | Air in coolant circuit, bleed → Chapter |
014 | | |
Evaluation of temperature difference between flame monitor -G64- and overheating sensor -G189- | Air in coolant circuit, flame monitor -G64- defective, overheating sensor -G189- defective | Bleed → Chapter, check flame monitor -G64- → Chapter, check overheating sensor -G189- → Chapter |
015 | | |
Continuous shut-down | Air in coolant circuit, | Bleed → Chapter Clear fault memory → Chapter |
017 | | |
Overheating | Temperature too high (> 130 °C) at overheating sensor -G189- and coolant temperature sender for heater -G241- | Air in coolant circuit, bleed → Chapter Check overheating sensor -G189- → Chapter Check coolant temperature sender for heater -G241- → Chapter Clear fault memory → Chapter |
020 | | |
Glow plug for heater -Q9- | Defective | Renew |
021 | | |
Short circuit on the glow plug for heater -Q9- | Short circuit on the connection or in the glow plug | Renew if necessary. |
030 | | |
Combustion air blower -V6- | Blocked | Renew |
032 | | |
Combustion air blower -V6- | Open circuit | Check the connection, replace if necessary |
038 | | |
Fresh air blower -V2- | Open circuit | Check, |
039 | | Renew if necessary. |
Fresh air blower -V2- | Short circuit | |
041 | | |
Circulation pump -V55- | Open circuit | Check, replace if necessary |
042 | | and bleed coolant circuit → Chapter |
Circulation pump -V55- | Short circuit | |
047 | | |
Metering pump -V54- | Short circuit | Check, |
048 | | Renew if necessary. |
Metering pump -V54- | Open circuit | |
050 | | |
Continuous shut-down | Unsuccessful start attempts | Erase fault memory → Chapter. |
051 | | |
Time overrun | When blowing flame monitor -G64- cold with combustion air blower -V6- | Check flame monitor -G64- → Chapter. |
052 | | |
Time overrun | Safety time exceeded after several start attempts | Check: exhaust pipe fuel volume, combustion air induction |
053 | | |
Flame failure from the high control level | Metering pump -V54- (quantity delivered) Exhaust pipe (blocked) Combustion air (insufficient) | Check, |
054 | Flame monitor -G64- (values) | Replace if necessary → Chapter |
Flame failure from medium control level | The fault memory is cleared if the start is successful. | |
056 | Heater is permanently switched off. | |
Flame failure from low control level | Clear fault memory after checking and replacing. | Switch on heater once again. |
060 | | |
Coolant temperature sender for heater -G241- | Open circuit | Check water temperature, |
061 | | Check coolant temperature sender for heater -G241-, |
Coolant temperature sender for heater -G241- | Short circuit | Replace if necessary → Chapter |
064 | | |
Flame monitor -G64- | Open circuit | Flame monitor -G64- |
065 | | Checking → Chapter |
Flame monitor -G64- | Short circuit | |
071 | | |
Overheating sensor -G189- | Open circuit | Check, |
072 | | |
Overheating sensor -G189- | Short circuit | Replace if necessary → Chapter |
090 | | |
Heater control unit -J162- | Error in microprocessor, (memory present) | Replace if necessary → Chapter |
091 | | |
Interference voltage | In vehicle electrical system or other voltage sources | Rectify |
092 to 103 | | |
Heater control unit -J162- | Defective | Replacing → Chapter. |