Fault memory: Interrogating and erasing fault memory > < Functions which can be selected when using the fault readers V.A.G?1551/1552
Fault reader V.A.G 1551: connecting and selecting engine electronics control unit
Fault reader -V.A.G 1551-: connecting and selecting engine electronics control unit
Special tools and workshop equipment required
   
t  Fault reader -V.A.G 1551-
t  Cable -V.A.G 1551/3B-
  Note!
The vehicle system tester -V.A.G 1552- can be used instead of the fault reader -V.A.G 1551-, although a printout will not be possible in such cases.
Checking conditions
l  Battery voltage at least 11 V.
l  Fuse 21 OK
l  Earth connections on the front side of the gearbox casing, or in the cylinder head.
Work sequence
–  Remove driver side shelf.
  W00-0459
–  Connect fault reader -V.A.G 1551- with cable -V.A.G 1551/3B-.
–  According to the function desired, switch ignition on or start engine → Chapter, “Selectable Functions” table.
  Note!
t  If the display remains blank, check voltage supply for diagnostic connection according to fault finding programme: → Current flow diagrams, Electrical fault finding and Fitting locations
t  If the display does not indicate the messages described in the work sequence: → Fault reader operating instructions
t  If the message “Fault in the data transfer!” is displayed due to an input fault, remove wire from fault reader, reconnect it and repeat work sequence.
  E01-0124
Indicated on the display:
 
V.A.G - SELF DIAGNOSIS              HELP
1 - Rapid data transfer                 
or
appear alternately
–  Operate the fault reader taking into account the information on the display:
–  Press key 1 for “Rapid data transfer”.
–  Press keys 0 and 1 for address code “Engine electronics” and confirm entry with the Q key.
 
V.A.G - SELF DIAGNOSIS              HELP
2 - Flash code output                   
Indicated on the display:
t  6K0 906 030 B = Part No. of the control unit (see Parts Catalogue for the latest control unit version)
t  Marelli 1AV = System designation
t  S038 = Programme version
–  Press the key.
 
              Marelli 1AV             ->
Indicated on the display:
–  Continue in accordance with repair procedures.
 
Rapid data transfer                 HELP
Select function XX                      