seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Coolant pump and 4/2-way valve with thermostat > < Check the cooling system for leaks
Checking engine oil cooler for leaks
Checking engine oil cooler for leaks
Consult the equivalence table for tools and equipment according to applicability among Seat / VW / Audi / Skoda → Chapter.
   
Special tools and workshop equipment required
t  Refractometer -T10007A-, see equivalent → Anchor
t  Hose clamps up to Ø 25 mm -3094-, see equivalent → Anchor
t  Coolant tester -V.A.G 1274B-, see equivalent → Anchor
t  Adapter for cooling system tester -V.A.G 1274/8-, see equivalent → Anchor
t  Collector tray for workshop crane -VAS 6208-, see equivalent → Anchor
t  Pliers for spring-loaded band-type clamps -VAS 6499-, see equivalent → Anchor

   
t  Torque wrench -V.A.G 1331-, see equivalent → Anchor.
Not illustrated
t  Expansion tank -1K0 121 407 A- or expansion tank -1J0 121 407 B-
t  Sealing cap -191 211 343-
t  Sealing cap -1J0 121 324-
t  Coolant hose -251 265 056-
Prerequisites:
l  Engine cold
Checking sequence
–  Remove the underbody protection → Bodywork, exterior assembly work; Rep. gr.50.
–  Drain coolant → Chapter.
–  Loosen hose clip on engine oil cooler with spring-type clip pliers -VAS 5024-.
–  Remove engine oil cooler with housing. → Chapter
  Note
t  Collect escaping coolant with drip tray -V.A.G 1306- or drip tray -VAS 6208-.
t  Collect leaking engine oil with a cleaning cloth, if necessary.
  W00-0427
Checking the removed state
–  Clamp housing with old seal on a suitable, level and clean surface.
–  Attach plug-2- to venting connection of expansion tank -1-.
–  Secure coolant hose -3- on engine oil cooler and expansion tank.
–  Fill expansion tank up to „Max“ marking.
–  Fit cooling system tester -V.A.G 1274- with adapter for cooling system tester -V.A.G 1274/8- to expansion tank.
–  Build up pressure with hand pump on cooling system tester. Approx. 1.6 bar pressure.
–  Observe pressure drop on pressure gauge. A pressure drop within 10 minutes is not permitted.
If the pressure drops:
–  Renew engine oil cooler → Chapter.
Installation is carried out in the reverse sequence; note the following:
–  Renew seal for housing.
–  Check coolant level and, if necessary, replenish → Chapter.
–  Check engine oil level, replenish engine oil if necessary → Chapter.
  N19-10280

Coolant pump and 4/2-way valve with thermostat > < Check the cooling system for leaks