Checking the removed state |
–
| Clamp housing with old seal on a suitable, level and clean surface. |
–
| Attach plug-2- to venting connection of expansion tank -1-. |
–
| Secure coolant hose -3- on engine oil cooler and expansion tank. |
–
| Fill expansion tank up to „Max“ marking. |
–
| Fit cooling system tester -V.A.G 1274- with adapter for cooling system tester -V.A.G 1274/8- to expansion tank. |
–
| Build up pressure with hand pump on cooling system tester. Approx. 1.6 bar pressure. |
–
| Observe pressure drop on pressure gauge. A pressure drop within 10 minutes is not permitted. |
Installation is carried out in the reverse sequence; note the following: |
–
| Renew seal for housing. |
–
| Check coolant level and, if necessary, replenish → Chapter. |
–
| Check engine oil level, replenish engine oil if necessary → Chapter. |
|
|
|