| Insert a new valve into guide. The end of the valve stem must be flush with the edge of the guide. On account of differing stem diameters, always use inlet valve in inlet guide and exhaust valve in exhaust guides. |
–
| Determine amount of sideways play. Wear limit: 0.8 mm. |
|
|
|