seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Measuring radial clearance of camshafts > < Valve control: Exploded view of components
Measuring axial clearance of camshaft
Measuring axial clearance of camshaft
Special tools and workshop equipment required
   
t  Universal dial gauge bracket -VW 387-
  W00-0037
t  Dial gauge -VAS 6079-
  W00-1261
Operation process
–  Remove retainer frame.
–  Secure dial gauge -VAS 6079- with universal dial gauge bracket -VW 387- to retaining frame as shown in illustration.
–  Press camshaft against dial gauge by hand.
–  Set dial gauge to „0“.
–  Press camshaft away from dial gauge and read off value:
Axial clearance of inlet and outlet camshafts:
l  Specification: 0.048 ... 0.118 mm.
l  Wear limit: 0.17 mm.
  A15-10637