Leon Mk2
Engine code BMT |
1 - | Seal |
q | Renewing |
2 - | Intake manifold |
3 - | Seal |
q | Renewing |
4 - | Shaft end |
q | The cylinder head cover must be dismantled for removal → Chapter |
5 - | Intake manifold flap motor -V157- |
q | The flap in the vacuum tube closes for approx. 3 seconds for the engine shut down process and then opens again thereafter. In this way, the stopping juddering is prevented. |
6 - | Comes from the supercharger |
7 - | 10 Nm |
8 - | Exhaust gas recirculation valve -N18- with exhaust gas recirculation potentiometer -G212- |
q | Before fitting, check and, if necessary, clean the sealing surface on the supercharger. |
q | When the exhaust gas recirculation valve -N18- with exhaust gas recirculation potentiometer -G212- has been replaced, the ignition must be turned on and back off again. Then wait a minute for the coolant advance of the control device (the valve adjusts itself, the main relay must click) |
q | Start engine and run for few minutes at idling speed. |
q | Then read-out the fault memory of the control unit; no fault should be registered in the fault memory → Chapter |
q | If a malfunction is registered in the fault memory, erase the memory and repeat the sequence of operations. |
9 - | Seal |
q | Renewing |
10 - | Connecting pipe |
q | for the exhaust gas recirculation valve |
q | Exhaust gas recirculation radiator - assembly overview → Chapter |
11 - | 22 Nm |
12 - | 22 Nm |