Checking fuel tank breather
Checking fuel tank breather
Checking fuel tank breather
Special tools and workshop equipment required
t
Hand vacuum pump -VAS 6213-
Test prerequisite
l
Ignition must be switched off.
Test procedure
–
Pull off breather line (white)
-1-
. To do this, press release button.
–
Then connect hand vacuum pump -VAS 6213- as shown to breather line.
–
Operate hand vacuum pump -VAS 6213- several times. Vacuum must not build up.
–
Detach hose
-1-
from activated charcoal filter.
–
Seal breather hole and connection on activated charcoal filter
-arrows-
and operate vacuum pump several times again. Vacuum must build up.
–
If vacuum does not build up, renew activated charcoal filter.
Power unit