seat Workshop Repair Guides

SEAT Workshop Service and Repair Manuals

Engine lubrication > < Turbulence chamber
Removing
Removing
l  Cylinder head removed
–  Remove the injectors: → Rep. Gr.23.
–  Separate all of the glow plugs using the -U-40082- glow plug socket spanner.
–  Expel the turbulence chamber by tapping through the injector placement using a hammer.
–  Remove the combustion residue from the contact surfaces of the cylinder head turbulence chamber.
–  Fit a new turbulence chamber; the assembly position will be determined by the groove and the guide tab.
–  Insert the turbulence chamber by using a plastic mass.
–  Measure the protrusion of the turbulence chamber: Theoretical value: 0.07 mm maximum
If the specification is exceeded:
–  Replace the cylinder head → Chapter.
   

Engine lubrication > < Turbulence chamber