Checking hydraulic compensation elements
Checking hydraulic compensation elements
  Note
t  The hydraulic compensation elements cannot be repaired.
t  Irregular valve noise during starting is normal.
Special tools and workshop equipment required
t  Feeler gauges
Procedure
–  Start engine and run until the radiator fan has switched on once.
–  Increase engine speed to about 2500 rpm for 2 minutes; perform road test if necessary.
  Note
If the irregular valve noises stop but recur repeatedly during short journeys, the oil retention valve must be renewed. The oil retention valve is located in the oil filter bracket → Chapter.
–  If the hydraulic compensation elements are still noisy, find out which is the defective compensation element as follows:
–  Remove cylinder head cover → Chapter.
–  Turn crankshaft by the bolt for the toothed belt wheel until cam of supporting element to be tested is facing upwards.
   
–  Press roller rocker finger downwards -arrow- to check clearance between cam and roller rocker finger.
–  If a 0.20 mm feeler gauge can be inserted between cam and roller rocker finger, replace hydraulic compensation element.
Concluding measures
–  Install cylinder head cover → Chapter.
  A15-1011