Installing the hose connections with couplings |
Note t
| The charge air system must be free of leaks. |
t
| The hose connections and the hoses for the charge air system must be free of oil and grease before the assembly. |
t
| Apply a silicon-free and oil free grease for rubber on the sealing surface and the oil seal. Any grease containing silicon or oil may not be used. |
t
| Replace the joint rings where damaged. |
t
| Insert the oil seal into the groove of the air charging hose and see that the groove is contact on the entire periphery, so that it is not damaged. |
t
| Secure all hose connections with the correct hose clips (same as original equipment) → Parts catalogue. |
t
| For a secure attachment of the charge air pipes to their connections, an anti-corrosive spray must be applied to the bolt thread in used clips before the assembly. |
Caution The coupling seal may be damaged if the safety fastener is locked when carrying out the assembly. This will cause leaking. Observe the assembly instructions. |
|
|
|
|