Testing vacuum system
Testing vacuum system
Special tools and workshop equipment required
   
t  Manual vacuum pump -VAS 6213-, see equivalency → Anchor
Operation process
–  Check all the vacuum lines of the entire vacuum system. When doing so, keep in mind the following:
t  Cracks
t  Rodents bites ?
t  Kinked or crushed lines
t  Lines porous or leaking
–  Check the vacuum hose to solenoid valve and from solenoid valve to relevant component.
–  If a fault is stored in the event memory, check the vacuum lines leading to the corresponding component and also check the remaining vacuum lines leading to other components.
–  If no pressure is built up or the pressure falls again immediately when using the vacuum pump -VAS 6213-, ensure that the manual vacuum pump and the coupling hoses are sealed.