| Immerse the injectors with the injection module holder -VAS 6418/1- in the cleaning fluid. |
–
| Use dial control-4- to set the temperature to 50ºC. |
–
| Use dial control-5- to set the time to 30 minutes. |
–
| Switch on the ultrasonic apparatus from key -3-. |
Note As soon as the temperature reaches 50ºC, the set time starts running. |
–
| After cleaning each injector, always replace the gasket ring in the combustion chamber (Teflon gasket ring) → Chapter |
–
| Next, fit the injectors back into place → Chapter. |
|
|
|