| Connect test instrument/DSO adapter (5-pin) -VAS 5565- to connector and fuel delivery unit. |
–
| Connect the ammeter clip -A-to the red cable marked „Stromzange (ammeter clip)“ on theDSO (5 contact) adapter for the measuring/oscilloscope module -VAS 5565-. |
–
| Start engine and run at idling speed. |
–
| Measure the power consumption of the fuel pump: |
l
| Specification: 9 Amps maximum |
Note t
| The starting current of the fuel pump can be more than the specification for a short period when starting the motor. |
t
| When an irregular fault of the fuel system occurs sporadically, the inspection can also be carried out for a test drive. The help of a second mechanic will be needed. |
If the current draw is exceeded: |
–
| Fuel pump is defective, renew fuel delivery unit → Chapter. |
|
|
|