Detach the 3-contacts connector from the Hall sender -arrow-.
–
To test the voltage, connect the multimeter to contacts 1 (positive) and 3 (earth) of the connector at the Hall sender, using the auxiliary leads of the -V.A.G. 1594 A-.
–
Switch on the ignition. Target value: 4.5 V min
–
Switch off the ignition.
If there is no voltage:
–
Connect the test box -V.A.G. 1598/31- to the wiring harness of the control unit, without connecting the engine control unit.
–
Test for open circuits in the wiring between the test box and the triple connector, following the wiring diagram. Contact 1+female contact 98 Contact 2+female contact 86 Contact 3+female contact 108 Wire resistance: 1.5 Ω max.
–
Also test the wiring for short circuits between wires. Target value: ∞ Ω
If no wiring fault is detected and there is voltage between contacts 1 + 3: