–
| To test the voltage, connect the multimeter to connectors 3 + 4 (connector to the engine control unit), using the auxiliary leads of the -V.A.G. 1594 A-. |
–
| Switch on the ignition and test the basic voltage. Target value: 0.40...0.50 V |
–
| Switch off the ignition. |
If the target value is reached: |
–
| Replace the post-catalyst lambda probe -G130-. → Rep. Gr.26 |
|
|
|