Press keys 0 and 4 for the function “Introduction of basic setting” and confirm entry with key Q.
Rapid data transfer HELP
Select function XX
Indicated on display:
–
Press keys 0, 4 and 6 for “Display group number 46” and confirm entry with Q key.
Basic setting
Input display group number XXX
Indicated on display: (1...4 = Display fields)
–
Set engine speed to 1500...3900 rpm using speed regulator -V.A.G 1788/10-.
–
Maintain engine speed at 1500...3900 rpm until the display in display zone 4 jumps from “Test OFF” to “Test ON”. The catalytic converter temperature in display zone 2 must be at least 300 °C min.
Note!
This process may take a few minutes.
–
Continue to maintain the engine speed at 1500...3900 rpm until the result of the function test is displayed in display zone 4. Specification: “Cat B1 OK”
If “Cat. B1 not OK” appears in display zone 4:
–
Remove the engine speed adjuster -V.A.G 1788/10- from accelerator pedal.
–
Press →-key.
System in basic setting 46 →
Indicated on display:
–
Press keys 0 and 6 for the “End output” function and confirm input with key Q.