Indicated on the display: (1…4 = display zones) |
–
| Read off throttle valve angle in display zone 3. |
–
| Open the throttle valve slowly to full gas, observing the angle displayed in zone 3. The numerical value must increase uniformly within the entire range. |
–
| Press keys 0 and 6 for the “End output” function and confirm input with the Q key. |
If the figure does not increase uniformly: |
–
| Replace throttle valve control unit → Item. |
If the display constantly shows 0 ∠° or is above 90 ∠°: |
|
|
Read measured value block 3 -> | 1 2 3 4 |
|