The display reads: (1...2 = display fields) |
–
| Test the state of the pre-catalyst lambda regulation (display field 1): Target value: 1 1 1 (Meaning → Anchor). |
Note! t
| The first position of the 3-digit numerical block switches temporarily between 0 and 1 (lambda probe heating ON and OFF). |
t
| Depending on the state of lambda regulation, the 3-digit numerical may alternate between 0 and 1. |
t
| The bits in the display field 1 change to 1 when the catalyst temperature is above 400.0 °C ( → Anchor, display field 2). |
If the target value is not reached: |
If the target value is reached: |
–
| Change to group 32 as follows: |
–
| Press 0, 3 and 2 for “Display group number 32” and press Q to confirm the entry. |
|
|
Read measurement value block 30 -> | 1 2 |
|